NIKON / RIGHTON – Speedy-i, Speedy-i K Autorefrattometro

Current informatical society, eye fatigue, one of the typical modern diseases cause by eye accommodation issue is now easily discover by Speedy-i series during screening basis. Accommodative Micro Fluctuation result will show in graph for easy reading, plus opacity detection function makes Speedy-i Series the world first All-In-One Refractometers.

Speedy-i and Speedy-i K, a New Generation of “All In One” system with Auto Refractor, Keratometer, Auto Find (Opaque Media) and Accommodative Micro Fluctuation

3 in 1 Function
With combination of Refractometer (Keratometer, K-Model), Accommodative Micro Fluctuation, Opaque Media (opacity) screening, the measurement speed is vastly improved to only 49 sec (one eye).

Reduce of accommodation testing time
Measurement speed increased 20% compare with previous model. With the new SCR (Screening) mode, an eye can be tested in just 49 seconds.

Objectively find the cause of eye fatigue
Patient’s individual AMF (Accommodative Micro Fluctuation) value will be analyzed and from the data, High Frequency Components (1 – 2.3Hz) will be extracted and based on measurement data, chart location, accommodation reaction value and pupil size to formulate FK map (Frequency of Kinetic reaction).

ADD Function
The ADD function enable a patient’s near point power to be measured objectively by applying accommodative stimulation. And auto AMF can detects if the power gives the patient eye strain or not by color indication.

Residual Astigmatism Calculation (Only for K-model)
Residual astigmatism calculation, necessary for CYL contact lenses and CYL IOL prescriptions, is automatically conducted and results printed out (K-Model).

Astigmatism corresponding meridian target
By adopting a new fireworks chart, patient with astigmatism are able to focus on either one of the lines.

i-File software (options)
Data can be managed by using i-File and view saved record using Internet Explorer

SPECIFICATIONS

Measurement range:
– S-20.00D – +23.00D retinoscopy principle
– C+/- 12.00D
– Axis 0-180°
Minimum required pupil size: Φ2.3 mm
Corneal size measurement: 0 – 16.0mm (manually)
Radius curvature: 5.00 – 11.00mm
Corneal astigmatism: 0 – 12.00D
Axis: 0 – 180°
Residual astigmatism range: 0 – 12.00D
Residual astigmatism axis: 0 – 180°
Measurement range (center of cornea): Φ3.2 (R8.0mm)
Measurement range (peripheral of cornea): Φ6.8 (R8.0mm)
PD range: 1 to 83mm
Fixation: Firewor
Chin rest movement range: 65mm (From initial line of main body to chin table min. 61mm max. 131mm)
Pupil size measurement: 2.0mm – 12mm
Dimensions: 254 (W) x 474.5 (L) x 478 (H)mm
Weight: 14kg

Marca

,